Brand Name : Fluke
Model Number : Fluke 9530 Active Head
MOQ : 1
Payment Terms : L/C,D/A,D/P,T/T,Western Union,Western Union,T/T,MoneyGram
Delivery Time : 3-5 days
New / Used : Used
Leveled-Sine Frequency Range : 0.1 Hz – 3.2 GHz (when driven by a 9500B mainframe)
Fast-Edge Rise Time : Selectable 150 ps or 500 ps pulses for bandwidth verification
Amplitude Range : 5 mV p-p – 3 V p-p into 50 Ω (full band)
Output Connectivity : Active-Head Technology™ with SMA/BNC connector; auto-ID and remote amplitude/polarity control via 9500B calibrator
Calibration Coverage : Verifies oscilloscope bandwidths up to 3.2 GHz without recabling (supports up to five simultaneous heads)
Fluke 9530 — 3.2 GHz Fast-Edge/Leveled-Sine Active Head
Designed for the Fluke 9500B oscilloscope calibrator, the 9530 active head brings 3.2 GHz leveled-sine generation and ultra-clean 150 ps / 500 ps edges right to the oscilloscope input. The head’s three-path, surface-mount design produces 5 mV–3 V signals with ppm-level flatness, revealing gain droop, slew-rate limits and time-base errors on modern 2–3 GHz scopes in a single connection. Active-Head Technology embeds control electronics in the connector, so amplitude, polarity and edge mode are set from the 9500B front panel or over GPIB/RS-232, eliminating manual recalibration. With auto-ID, hot-swap capability and support for up to five identical heads, the 9530 streamlines multi-channel verification, cuts setup time and retains traceable accuracy between services—delivering metrology-grade performance at a pre-owned price point.
Interested in Fluke 9530 Active Head or a similar model?
Drop your WhatsApp number or e-mail on our website and we will:
Send a tailored quotation and any current promotions.
Provide extra photos, test data, and full configuration details.
Discuss shipping, duties, warranty, and any other specifics you need.
Looking for other models? Our inventory changes daily—ask for the latest list of spectrum analyzers and RF equipment.
Every unit is calibrated at an ISO/IEC 17025 accredited laboratory. The original calibration certificate, marked TESTRO Certified, is linked to the unit’s serial number and included in the shipment.
A set of high-resolution teardown photographs showing seals, fasteners, and all critical modules.
A live video session in which an engineer demonstrates gain-linearity, noise-floor, and spurious-response tests in real time.